Product type | Uninterrupted power supply; Offline |
Capacity | 600VA/300W |
Product type | Uninterrupted power supply; Offline |
Capacity | 600VA/300W |
Input | Phase: Single |
Voltage: 110/120 VAC or 220/230/240 VAC | |
Voltage range: 90~145 VAC / 170~270 VAC ±4VAC | |
Frequency: 50 / 60Hz | |
Frequency range: Min. 43HZ | |
Output | Phase: Single |
Voltage: 120 VAC or 220 VAC | |
Voltage regulation ( Batt. mode ): ± 10% | |
Frequency: 50 Hz or 60Hz | |
Frequency redulation ( Batt. mode ): ±1Hz | |
Output waveform ( Batt. mode ): Modified sinewave | |
Power factor | 0.5 |
Battetry | Battery type & number: 12V/7,2Ah *1 pc |
Back up time ( at a PC load with 15″ monitor ): 13~ 20 minutes |
|
Recharge time: 10 hours to 90% after complete discharge | |
Transfer time | Typical: 2-6ms, 12ms Max |
Indicator | AC mode: Green lighting |
Battery mode: Green LED flashing every 4 seconds | |
Low battery at battery mode: Green LED flashing every second | |
Fault: Red LED lighting | |
Battery weak at AC mode: Red LED flashing every 2 seconds for 30 seconds | |
Battery fault at AC mode: Red LED flashing 3 times every 2 seconds | |
Overload: N/A | |
Audible alarm | Battery mode: Sounding every 4 seconds |
Low battery at battery mode: Sounding every second | |
Fault: Continuously Sounding | |
Battery weak at AC mode: Sounding every 2 seconds for 30 seconds | |
Battery fault at AC mode: Sounding 3 times every 2 seconds | |
Battery replacement: N/A | |
Overload: N/A | |
Protection | Full protection: Discharge, overcharge, and overload protection |
Physical | Dimension, D*W*H (mm): 176.5*80*230 |
Net weight (kg): 3.1 | |
Environment | Operating Environment: 0- 40°C, 0-90 % relative humidity (non-condensing) |
Noise Level: Less than 40dB | |
Interface | Smart RS-232: N/A |
USB Port: N/A | |
Accessories | IEC output cable x1, User guide |
15x15 product image 300dpi PowerMust400 Offline-tower.jpg | 0.9mb | 14-07-2017 | |
15x15 product image 300dpi PowerMust1000 Offline-back.jpg | 0.8mb | 14-07-2017 | |
15x15 product image 300dpi PowerMust600 Offline-rack.jpg | 0.8mb | 14-07-2017 | |
15x15 product image 300dpi PowerMust 1000 Offline-tower.jpg | 1mb | 14-07-2017 | |
15x15 product image 300dpi PowerMust600 Offline-back.jpg | 0.7mb | 14-07-2017 | |
15x15 product image 300dpi PowerMust400 Offline-rack.jpg | 0.8mb | 14-07-2017 | |
15x15 product image 300dpi PowerMust600 Offline-tower.jpg | 0.9mb | 14-07-2017 |
Product info PM400,600,1000 Offline-En.pdf | 1.5mb | 14-07-2017 |
PowerMust 400 6001000 Offline-FR.pdf | 0.5mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-RO.pdf | 1.2mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-IT.pdf | 0.6mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-CZ.pdf | 0.4mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-UA.pdf | 0.9mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-SV.pdf | 0.8mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-PT.pdf | 0.4mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-TR.pdf | 0.6mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-ES.pdf | 0.4mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-FI.pdf | 0.4mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-RU.pdf | 0.9mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-NL.pdf | 0.4mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-GR.pdf | 0.9mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-En.pdf | 0.4mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-PO.pdf | 0.6mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-DK.pdf | 0.4mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-DE.pdf | 1mb | 14-07-2017 | |
PowerMust 400 6001000 Offline-HR.pdf | 0.4mb | 14-07-2017 |